Instruction manual
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8237801
42
Error Codes
Following is a list of possible error codes for an
electronic control. Errors beginning with “EI” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.
Display Description
Cause/
Corrective Action
EI01 Transmission Failure Communication failure. Re-aim external device and try
again.
EI02 Time-out Error Communication failure. Re-aim external device and try
again.
EI03 Invalid Command Code Communication successful, but the command was not
valid for this machine type, or the control could not
perform the command in its current mode of operation.
Ensure data is for current machine type and control is in
correct mode.
EI04 Expecting Upload Request Communication failure. Re-aim external device and try
again.
EI05 Invalid or Out-of-Range Data The value in at least one of the programming options is
invalid or out of range. Recheck the programming
option’s value and try again.
EI09 CRC-16 Error Communication failure. Re-aim external device and try
again.
EI0A Framing Error Communication error. Re-aim external device and try
again.
EI0C Time-out Exceeded Communication error. Re-aim external device and try
again.
EI0E Encryption Error Communication error. Re-aim external device and try
again. If the problem persists, check that the security
code is correct.
EI0F Infra-red Disabled Communication failure or infra-red is disabled.
Manually enable infra-red on control or re-aim external
device and try again.
E FL Fill Error Water level not reached within 10 minutes in any fill
agitate cycle. End cycle. Power down machine to clear.
E SP SPI Communications Error Front End control cannot communicate with output
board. Power down the machine, power up and try
again.
E dL Door Lock Error Door does not lock immeadiately upon closing (open
and reclose door) or doesn’t unlock 5 seconds after cycle
completion. Power down machine and retry.
Table 14 (continued)