Table 13 (continued)
Production Test Cycle Quick Reference Chart
Display Test Mode Comments
xxxF” degrees F or
xxxC” degrees C
depending on the
Fahrenheit/Celsius
programming parameter
Heat water to 110°F or display temperature xxx is degree temperature. This step
skipped if not model with heat. Heater
turned off when temperature reached.
LoAg Reduced Wash Speed Forward with no agitation
action
This step skipped on 2 Speed models.
Ag Wash Speed Forward with no agitation action
rAg Wash Speed Reverse with no agitation action
drAI Drain Distribution Speed
PUrg Factory Valve Purge
SP 1 Extract Speed #1 “very low” This step skipped on 2 Speed models.
SP 2 Extract Speed #2 “low” This step skipped on 2 Speed models.
SP 3 Extract Speed #3 “medium” This step skipped on 2 Speed models.
SP 4” (VFD Models) or
SPIn” (2 Speed Models)
Extract Speed #4 “high” Design 2 models only. This step skipped on
F-Speed Models.
SP 5 Extract Speed #5 “ very high” Design 2 models only. This step skipped on
2 Speed and F-Speed Models.
SP 6 Extract Speed #6 “ultra high” Design 2 models only.
Prdn End of test Turn Power off.
Table 13