Instruction manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
F8237801
40
Production Test Cycle Quick Reference Chart
Display Test Cycle Step Comments
S xx FEC Control Software Version xx is the software version number.
o xx Output Board Software Version xx is the software version number.
Ct 2 Control Type 2 is the control type.
oPL Control Type OPL
USA” or “IntL Control Type Domestic or International
drAn” Drain Type
tEnP Temp Sensor Step skipped if not equipped with temp sensor.
HEAt Heater Step skipped if not heater-equipped.
rot Rotation Sensor Step skipped if not Rotation Sensor-equipped.
L dC” or “L AC Door Lock Type L dC” if 24 VDC lock or “L AC” if 240 VAC
unlock solenoid.
droP” or “drCL Door Status Door open or closed.
drUL” or “drLo Door Lock Status Door will lock.
8.8.8.8” + all LEDs Display Test All display elements are lit.
PAxx” where xx = 1 through 12 Keypad Test step Advance after all keypads are pressed.
A xx Top Cover Switch Test xx is eitherCL” for closed or “oP” for open.
Cxxx” Machine Type/Size
drxx Drive Software Version Number xx is the drive software version number. Design 2
models only.
dPxx Drive Parameter Table Version
Number
xx is the drive parameter table version number.
Design 2 models only.
dt x Drive Type Value xx is the drive type value. Design 2 models only.
HFIL Hot Fill to Low Level All water outputs turned off when Low Level
reached.
CFIL Cold Fill to Low Level All water outputs turned off when Low Level
reached.
bFIL Warm Fill to Low Level All water outputs turned off when Low Level
reached.
bFIH Warm Fill to High Level All water outputs turned off when High Level
reached.
S1” for supply or “C2Co
for compartment
Supply #1 or Compartment
#2 Cold Fill
S2” for supply or “C2Ho
for compartment
Supply #2 or Compartment
#2 Hot Fill
S3” for supply or “C3Co
for compartment
Supply #3 or Compartment
#3 Cold Fill
S4” for supply or “C4Ho
for compartment
Supply #4 or Compartment
#4 Hot Fill
Table 13 (continued)