Instruction manual
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
39
F8237801
Drive Software Version Number Test
(Design 2 models only)
This option displays the custom drive software version
number. To start test, control must be in the Diagnostic
Testing Mode. Refer to How to Enter Diagnostic
Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “drxx” where “xx” is the custom drive
software version number.
To exit the Custom Drive Software Version Number
Test, press the #3 (<) keypad. The control will return
to the Diagnostic Testing Mode.
Drive Parameter Table Version Number
(Design 2 models only)
This option displays the custom drive parameter table
version number. To start test, control must be in the
Diagnostic Testing Mode. Refer to How to Enter
Diagnostic Testing Feature at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show “dPxx” where “xx” is the custom drive
parameter table version number.
To exit the Custom Drive Parameter Table Version
Number Test, press the #3 (<) keypad. The control will
return to the Diagnostic Testing Mode.
Drive Type Value (Design 2 models only)
This option displays the custom drive type value. To
start test, control must be in the Diagnostic Testing
Mode. Refer to How to Enter Diagnostic Testing
Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “dt x” where “x” is the custom drive type
value. Refer to Table 12.
To exit the Custom Drive Type Value, press the #3 (<)
keypad. The control will return to the Diagnostic
Testing Mode.
Production Test Cycle
To Enter Production Test Cycle
1. Be certain control is in Ready Mode and top
cover is open.
2. While pressing and holding the #3 keypad with
one hand, press the #7 keypad with the other
hand.
3. When the control enters the Production Test
Cycle, it will first display “Sxx” with the “xx”
showing the software version of the front end
control.
4. The control will advance through the sequence of
test steps whenever any key is pressed. Refer to
Table 13 for all tests in the Production Test
Cycle.
To Exit Production Test Cycle
To exit a test step, power down the machine.
Display Drive Type
“dt 1” 2 HP drive
“dt 2” 3 HP drive
“dt 3” 5 HP 280V drive
“dt 4” 5 HP 480V drive
Table 12