Programming Control
F8237801
32
12. Cool Down Enable/Temperature
“Codn”
This option allows the owner to enable or disable the
Cool Down Water Temperature option. If enabled, the
owner can also set the cool down water temperature.
How to Program Cool Down Enable/
Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
“Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “Codn”
appears in the display.
4. When “Codn” appears in the display, press the
START (enter) keypad. A number or “oFF” will
appear in the display. The number corresponds to
the current Cool Down Water Temperature value
and “oFF” appears when cool down is disabled.
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
NOTE: Cool Down Water Temperature is
selectable between 50° and 160° Fahrenheit (10°
and 71° Celsius). Default is off.
6. Press the START (enter) keypad when the
desired value appears in the display.
NOTE: Refer to option 8 to select Celsius or
Fahrenheit display.
7. Press the START (enter) keypad when the correct
number appears in the display. The next option,
“PtEn”, will appear in the display.
NOTE: To program “PtEn” (Production Test Cycle
[on/off]), refer to option 13. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
13. Production Test Cycle (On/Off)
“PtEn”
This option allows the owner to enable or disable
access to the production test cycle. Refer to
Production Test Cycle section for more information.
How to Program the Production Test
Cycle (On/Off)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
“Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “PtEn”
appears in the display.
4. When “PtEn” appears in the display, press the
START (enter) keypad. The current Production
Test Cycle status will appear in the display.
“on” = Option Enabled (Default Setting)
“oFF”= Option Disabled
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “rAEn”, will appear in the display.
NOTE: To program “rAEn” (Manual Rapid
Advance [on/off]), refer to option 14. To program
other options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
>
<
>
<
>
<
>
<
>
<
>
<