Instruction manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
31
F8237801
10. Warm Water Temperature
“FHC”
This option allows the owner to program the warm
water temperature for models equipped with heat.
How to Program Warm Water Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “FHC
appears in the display.
4. When “FHC” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Warm Water Temperature value.
5. Press the #3 ( ) or the #6 ( ) keypad to increase
or decrease the current Warm Water Temperature
value to the desired Warm Water Temperature
value.
NOTE: Warm Water Temperature is selectable
between 35° and 194° Fahrenheit (2° and 90°
Celsius). Default temperature is 100° Fahrenheit
(38° Celsius).
NOTE: Refer to option 8 to select Celsius or
Fahrenheit display.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
FC”, will appear in the display.
NOTE: To program “FC” (Cold Water
Temperature), refer to option 11. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
11. Cold Water Temperature “FC”
This option allows the owner to program the cold
water temperature for models equipped with heat.
How to Program Cold Water Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3
() or the #6 ( ) keypad to scroll
through the programmable options until “FC
appears in the display.
4. When “FC” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Cold Water Temperature value.
5. Press the #3 ( ) or the #6 ( ) keypad to increase
or decrease the current Cold Water Temperature
value to the desired Cold Water Temperature
value.
NOTE: Cold Water Temperature is selectable
between 35° and 194° Fahrenheit (2° and 90°
Celsius). Default temperature value is 35°
Fahrenheit (2° Celsius).
NOTE: Refer to option 8 to select Celsius or
Fahrenheit display.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
Codn”, will appear in the display.
NOTE: To program “Codn” (Cool Down Enable/
Temperature), refer to option 12. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
<
<
<
To prevent personal injury, avoid contact
with inlet water temperatures higher than
125° Fahrenheit (51° Celsius) and hot
surfaces.
W748
WARNING
>
<
>
>
<
To prevent personal injury, avoid contact
with inlet water temperatures higher than
125° Fahrenheit (51° Celsius) and hot
surfaces.
W748