Instruction manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
29
F8237801
6. Number of Balance Retries
“bALr” (Variable Frequency
Drives Only)
This option allows the owner to program how many
times the control will retry balancing the load before
moving into Extract step.
How to Program Number of Balance
Retries
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad, and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “bALr
appears in the display.
4. When “bALr” appears in the display, press the
START (enter) keypad. The current value will
appear in the display.
5. Press the #3 ( ) or the #6 ( ) keypad to increase
or decrease the current value.
NOTE: The number of balance retries can be set
from 1-7. The default value is 3 for Design 1 models
and 1 for Design 2 models.
6. Press the START (enter) keypad when the
desired value appears in the display. The next
option, “IrA”, will appear in the display.
NOTE: To program “IrA” (IR Access [on/off]),
refer to option 7. To program other options, refer to
the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
7. IR Access (On/Off) “IrA”
This option allows the owner to enable or disable
allowing the control to be read by an external device.
How to Program the IR Access (On/Off)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “IrA
appears in the display.
4. When “IrA” appears in the display, press the
START (enter) keypad. The current IR Access
status will appear in the display.
on = Option Enabled (Default Setting)
oFF = Option Disabled
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “tFC”, will appear in the display.
NOTE: To program “t FC” (Fahrenheit/Celsius),
refer to option 8. To program other options, refer to
the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to