Instruction manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
27
F8237801
Programming Extract Step
1. WhenSPIn” appears in the display, press the
START (enter) keypad. The first Extract step
programming option will appear in the display.
2. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable Extract step options.
Refer to Table 9.
NOTE: Extract Step “SPEn” must be enabled to
scroll through all Extract step options.
3. Press the START (enter) keypad when the
desired option appears in the display. The current
status/value will appear in the display. Refer to
Table 9.
4. Press the #3 ( ) or the #6 ( ) keypad to change
the current status/value.
5. Press the START (enter) keypad when the
desired status/value appears in the display. The
next Cycle Segment step option, “SEg2” will
appear in the display.
NOTE: To program “Cnin” (Cycle Time), continue
to next Cycle Segment option. To program other
options press the #3 ( ) or the #6 ( ) keypads and
refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
>
<
Extract
Step
Description Status/Value
SPEn Extract Step
Enable/Disable
on”/“oFF
SSEC Extract
Seconds
0” - “59
SnIn Extract Minutes Intermediate Extract:
Minimum
Step Time =30” seconds
Maximum
Step Time =3:59” minutes
Final Extract:
Minimum
Step Time =30” seconds
Maximum
Step Time =9:59” minutes
SSPd Extract Speed
(Design 1 -
VFD only)
1” = very low speed (80)
2” = low speed (80)
3” = medium speed (100)
Extract Speed
(Design 2 -
VFD only)
1” = very low speed (27)
2” = low speed (80)
3” = medium speed (100)
4” = high speed (125)
5” = very high speed (150)
6” = ultra high speed (200)
Table 9
>
>