Programming Control
17
F8237801
Figure 5
CHM1394R
CHM1394R
“0” - “255”
“SUPL” - Program Supply Step Options
“AgSt” - Program Agitate step options
“SSEC” - Extract Seconds:
“0” - “59”
“Cnin” - Program Cycle Time
(in minutes)
“dISP” - Dispenser Options:
Press START (enter) to access options
“SdUr” - Supply Duration:
Press START (enter) to access options
“SPEn” - Extract Step Enable/Disable:
“on” = Enable
“oFF” = Disable
“SnIn” - Extract Minutes:
“30” - “3:59” (Intermediate Step)
“30” - “9:59” (Final Step)
“SUEn” - Supply Step Enable/Disable:
“on” = Enable
“oFF” = Disable
“AgEn” - Agitate Step Enable/Disable:
“on” = Enable
“oFF” = Disable
“AdUr” - Agitate Duration (min):
“1” - “30”
“HEAt” - Heat in Agitate
(Heat present only):
“1” = To target
“2” = Maintain
“SSPd” - Extract Speed (Design 1 - VFD only):
“1” = Very Low Speed (80)
“2” = Low Speed (80)
“3” = Medium Speed (100)
(continued)
(continued)
(continued) (continued)
“SEC” - Seconds:
“0” - “59”
“nIn” - Minutes:
“0” - “9”
“drAn” - Enable/Disable Drain Step
“SPIn” - Program Extract Step Options
Drain Step Enable/Disable:
“on” = Enable
“oFF” = Disable
“S4” - Supply #4:
“on” = Enabled
“oFF” = Disabled
“C2” or “S1” -
Compartment #2/
Supply #1:
“on” = Enabled
“oFF” = Disabled
(Design 1 Models)
“C3” or “S2” -
Compartment #3/
Supply #1:
“on” = Enabled
“oFF” = Disabled
(Design 1 Models)
“C4” or “S3” -
Compartment #4/
Supply #3:
“on” = Enabled
“oFF” = Disabled
(Design 1 Models)
“C2” - Compartment #2
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“C3” - Compartment #3
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“C4” - Compartment #4
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“S1” - Supply #1
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“S2” - Supply #2
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“S3” - Supply #3
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“SSPd” - Extract Speed
(Design 2 - VFD only):
1 = Very Low Speed (27)
2 = Low Speed (80)
3 = Medium Speed (100)
4 = High Speed (125)
5 = Very High Speed (150)
6 = Ultra High Speed (200)