Instruction manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
15
F8237801
Table 2 (continued)
Option
Number
Option
Display
Description
Default
Value
Value Range
c. SnIn Extract Minutes ** Intermediate Extract:
Min. Step Time = 30 seconds
Max. Step Time = 3:59 minutes
Final Extract:
Min. Step Time = 30 seconds
Max. Step Time = 9:59 minutes
d. SSPd Extract Speed (VFD only) ** 1 - 3* (Design 1)
1 - 6* (Design 2)
c. Cnin”Cycle Time 0* 0 - 255 minutes
5“SUPC Supply/Compartment Dispenser
Programming (Design 1 models
only)
C C (Compartment)/S (Supply Dispenser)
6“bALr Number of Balance Retries
(VFD only)
Design 1: 3
Design 2: 1
1 - 7
7“IrA IR Access (On/Off) on on/oFF
8“tFC Fahrenheit/Celsius FAHr FAHr (Fahrenheit)/CEL (Celsius)
9“FH Hot Water Temperature 140°F (60°C) 35°F - 194°F/2°C - 90°C
10 FHC Warm Water Temperature 100°F (38°C) 35°F - 194°F/2°C - 90°C
11 FC Cold Water Temperature 35°F (2°C) 35°F - 194°F/2°C - 90°C
12 Codn Cool Down Enable/Temperature oFF oFF or 50°F - 160°F/10°C - 71°C
13 PtEn Production Test Cycle (On/Off) on on/oFF
14 rAEn Manual Rapid Advance
(On/Off)
on on/oFF
15 nCtd No Cycle Time Display oFF on/oFF
16 PCtd Programmable Cycle Time
Display
oFF on/oFF
17 SdAd Slow Drain Detection Adjust 0* 0 - 255 seconds
* Refer to programming section for value definition.
** Refer to the Cycle Chart for default cycle setting informaton.
Table 2