Instruction manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
F8237801
14
Table 2 (continued)
Option
Number
Option
Display
Description
Default
Value
Value Range
2. FILL Fill Step ––
a. FLEn Fill Step Enable/Disable ** on/oFF
b. FLEU Fill Level ** HI/nEd/Lo
c. tEnP Fill Temperature ** CoLd/Uarn/Hot
3. SUPL Supply Step ––
a. SUEn Supply Step Enable/Disable ** on/oFF
b. dISP Dispenser Options ** For Design 1 models, display will show Cx
(compartment-oriented) or Sx (supply-
oriented), depending on how option 5 (Supply/
Compartment Dispenser Programming) is
programmed. For Design 2 models,
Compartment and Supply dispensing is
programmed separately. Press START keypad
to access options.
(1) C2” or
S1
Compartment #2/Supply #1
(Design 1 models)
** on/oFF
(2) C3” or
S2
Compartment #3/Supply #2
(Design 1 models)
** on/oFF
(3) C4” or
S3
Compartment #4/Supply #3
(Design 1 models)
** on/oFF
(4) S4 Supply #4 (Design 1 models) ** on/oFF
(1) C2 Compartment #2 (Design 2 models) ** on/oFF
(2) C3 Compartment #3 (Design 2 models) ** on/oFF
(3) C4 Compartment #4 (Design 2 models) ** on/oFF
(4) S1 Supply #1 (Design 2 models) ** on/oFF
(5) S2 Supply #2 (Design 2 models) ** on/oFF
(6) S3 Supply #3 (Design 2 models) ** on/oFF
(7)
S4 Supply #4 (Design 2 models) ** on/oFF
c. SdUr Supply Duration ** Press START keypad to access options
(1) SEC Seconds ** 0 - 59
(2) nIn Minutes ** 0 - 9
4. AgSt Agitate Step ––
a. AgEn Agitate Step Enable/Disable ** on/oFF
b. AdUr Agitate Duration (in minutes) ** 1 - 30
c. HEAt Heat in Agitate
(if heater is present)
** oFF/1/2**
5. drAn”Drain Step ––
a. SPEn Extract Step Enable/Disable ** on/oFF
b. SSEC Extract Seconds ** 0 - 59
Table 2 (continued)