Instruction manual
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
F8237801
14
Table 2 (continued)
Option
Number
Option
Display
Description
Default
Value
Value Range
2. “FILL” Fill Step ––
a. “FLEn” Fill Step Enable/Disable ** on/oFF
b. “FLEU” Fill Level ** HI/nEd/Lo
c. “tEnP” Fill Temperature ** CoLd/Uarn/Hot
3. “SUPL” Supply Step ––
a. “SUEn” Supply Step Enable/Disable ** on/oFF
b. “dISP” Dispenser Options ** For Design 1 models, display will show “Cx”
(compartment-oriented) or “Sx” (supply-
oriented), depending on how option 5 (Supply/
Compartment Dispenser Programming) is
programmed. For Design 2 models,
Compartment and Supply dispensing is
programmed separately. Press START keypad
to access options.
(1) “C2” or
“S1”
Compartment #2/Supply #1
(Design 1 models)
** on/oFF
(2) “C3” or
“S2”
Compartment #3/Supply #2
(Design 1 models)
** on/oFF
(3) “C4” or
“S3”
Compartment #4/Supply #3
(Design 1 models)
** on/oFF
(4) “S4” Supply #4 (Design 1 models) ** on/oFF
(1) “C2” Compartment #2 (Design 2 models) ** on/oFF
(2) “C3” Compartment #3 (Design 2 models) ** on/oFF
(3) “C4” Compartment #4 (Design 2 models) ** on/oFF
(4) “S1” Supply #1 (Design 2 models) ** on/oFF
(5) “S2” Supply #2 (Design 2 models) ** on/oFF
(6) “S3” Supply #3 (Design 2 models) ** on/oFF
(7) “
S4” Supply #4 (Design 2 models) ** on/oFF
c. “SdUr” Supply Duration ** Press START keypad to access options
(1) “SEC” Seconds ** 0 - 59
(2) “nIn” Minutes ** 0 - 9
4. “AgSt” Agitate Step ––
a. “AgEn” Agitate Step Enable/Disable ** on/oFF
b. “AdUr” Agitate Duration (in minutes) ** 1 - 30
c. “HEAt” Heat in Agitate
(if heater is present)
** oFF/1/2**
5. “drAn”Drain Step ––
a. “SPEn” Extract Step Enable/Disable ** on/oFF
b. “SSEC” Extract Seconds ** 0 - 59
Table 2 (continued)