F8237801
Programming Control
What Can Be Programmed?
This feature allows the owner to program cycle
information and other features by using the keypads.
The control must have the Manual Programming
Mode enabled, which is the factory default. This mode
can only be turned “oFF” and “on” by using an
external device. Refer to this section when programming
the control.
This section offers a detailed description of all available
programmable options.
Each description includes instructions on when and
why the option might be used and, more importantly,
how to program the option.
For more advanced users, a quick reference list (refer
to Table 2) and programming flowcharts (refer to
Figure 4 through Figure 7) of the options available
through the programming mode are located on the
following pages.
NOTE: The letters and numbers in the Option
Display column of the Programmable Options List
are what will be shown in the display when that
option is selected.
Programmable Options Available
Option
Number
Option
Display
Description
Default
Value
Value Range
1“dCYC Default Cycle 51 - 9
2“AUd Audio Signal 29* 0 - 31
3“Err- Errors ––
a. EFL Fill Errors on on/oFF
b. Edr Drain Error on on/oFF
c. EUb Unbalance Error Display on on/oFF
d. EoP Open Thermister Error Display on on/oFF
e. ESH Shorted Thermistor Error Display on on/oFF
f. EHt Heat Error Display (Heater only) on on/oFF
g. LEr- Water Leak Detection Error
1. LEr1 Water Leak Detection During a
Machine Cycle (On/Off)
oFF on/oFF
3.
LEr3 Number of cycles between Leak
Detection Test
0* 0 - 127
h. E Sd Slow Drain Detection oFF on/oFF
4“CyC- Cycle Programming **
a. AgIt Cycle Agitate ––
1. tyPE”Agitate Type ** 1 - 2
2. ASPd Agitate Speed (VFD only) ** Lo/rEg
b. Seg- Cycle Segment Programming –1 - 8*
1. SgEn Segment Enable/Disable ** on/oFF
* Refer to programming section for value definition.
** Refer to the Cycle Chart for default cycle setting informaton.