Instruction manual
Error Codes
125
F232151
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
E:SP SPI Communications Error Master control cannot communicate with motor control.
Master control will try to reset the motor control by
powering it down. The error will display after three reset
attempt failures. Caused by transformer unplugged or
wiring to motor control incorrect.
E:OP Open Temperature Sensor Error Open temperature sensor circuit wiring. Replace sensor.
E:SH Shorted Temperature Sensor Error Short in temperature sensor circuit wiring. Replace
sensor.
E:dL Door Lock Error Door does not lock within 15 seconds of closing or 3
minutes after cycle completion. Open and reclose door.
E:dO Door Opened During A Running Cycle Control detects door open and door locked inputs high.
Caused by pulling on door while locked or about to lock.
Correct inoperative door locking system.
E:Ub Unbalance Error Unable to balance load. Redistribute load and run cycle.
E:Ht Heater Error Takes more than two hours to reach programmed heat
temperature. Replace faulty heater circuit components.
E:Pr Pressure Switch Sequence Error Pressure switches out of sequence. Replace pressure
switch.
Err Coin Error Invalid coin pulse or inoperative coin sensor. Check coin
drop area and remove obstructions. If error persists,
tampering may have occurred. Evaluate security
procedures.
Display Description
Cause/
Corrective Action
Table 12