Instruction manual
Testing Machine and NetMaster Functions
121
F232151
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
VFD Balance Adjustment Test
(VFD Models Only)
Upon entry, the display will show “BAL” and START
pad LED will flash until pressed to begin test. Door
will lock and motor will turn at Distribution Speed.
The display will show “PASS” (refer to Figure 227) if
the load is balanced and will show “FAIL” (refer to
Figure 228) if the load is unbalanced.
Figure 227
Figure 228
Water Purge Test
Upon entry, the display will show “PUrg” (refer to
Figure 229) and the START pad LED will flash until
pressed to begin test. Door will lock and display will
change to “FLSH” (refer to Figure 230). The Hot
water, Cold water and Auxiliary water valves and
Supply Dispensers #1, #2, #3 and #4 will turn on. Test
will end after two minutes.
Figure 229
Figure 230
CHM45R
CHM46R
CHM47R
CHM48R