Instruction manual

Testing Machine and NetMaster Functions
115
F232151
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Door Switch Input Test
If the loading door is open, the display will show
dr:OP”, Figure 212, or if the loading door is closed
the display will show “dr:CL”. Refer to Figure 213.
Figure 212
Figure 213
Door Lock Input Test
When the test is entered, the control will send a signal
to lock the door. It will check to make sure the door is
locked, and if it is, the display will show “dr:LO”.
Refer to Figure 214.
Figure 214
If the door is unlocked, it will showdr:UL”. Refer to
Figure 215.
Figure 215
Five seconds after sending the door lock signal, the
control will unlock it, check the door lock status and
display the status as shown above. This procedure is
repeated every time the START pad is pressed.
Show Fill Time Test
This test will display “Fx:xx”, the average low level
fill time in minutes and seconds. Refer to Figure 216.
The average fill time is calculated by taking the
average of the last four (4) fill times from the start of
the fill until the low-level pressure switch activates.
Figure 216
Show Drain Time Test
This test will display “dx:xx”, the average low
level drain time in minutes and seconds. Refer to
Figure 217. The average drain time is calculated by
taking the average of the last four (4) drain times from
med-level to low-level.
Figure 217
C627I
C628I
C629I
C630I
C631I
C632I