Instruction manual

Testing Machine and NetMaster Functions
F232151
114
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Pressure Switches Test
The display will show “Px1x2x3”, where “x1
represents the Low-Level switch, “x2” represents the
Medium-Level switch, and “x3” represents the High-
Level switch. Refer to Figure 207.
Figure 207
If any pressure switch is found open, its appropriate
digit will show “O”. Refer to Figure 208.
Figure 208
If it is closed, the display will show “C”. Refer to
Figure 209.
Figure 209
Access Panel Opening Test
Each time the access panel is opened, the count on the
display increases. The switch has to be closed for at
least one second, then open at least 1/2 second for a
valid count. This test will increment the access panel
opening counter and save the time/date for each
opening of the test. All further test openings have no
effect on the access panel opening counter.
Coin Vault Opening Test
Each time the coin vault is opened, the count on the
display increases. The switch has to be closed for at
least one second, then open at least 1/2 second for a
valid count. This test will increment the Coin Vault
opening counter and save the time/date for each
opening of the test. All further test openings have no
effect on the Coin Vault opening counter.
Coin Drop #1 Input Test
Each time a coin is entered, the count on the VFD
display increases. The display will showC1:xx”,
where “xx” indicates the number of coins entered
during the test. Refer to Figure 210.
Figure 210
Coin Drop #2 Input Test
Each time a coin is entered, the count on the VFD
display increases. The display will showC2:xx”,
where “xx” indicates the number of coins entered
during the test. Refer to Figure 211.
Figure 211
C623I
1 x1 Low-Level Switch
2 x2 Medium-Level Switch
3 x3 High-Level Switch
C623IE1A
C624I
3
2
1
C625I
C626I