Configuration #3 Display Test
Upon entry into this test, the control will display
Cxxx where xxx is a number corresponding to the
Machine Configuration #3 byte which is currently
unused.
VFD Balance Input Test
This test will display bA:OP (refer to Figure 223) if
the VFD balance switch is open (poor balance) or
bA:CL (refer to Figure 224) if the VFD balance
switch is closed (good balance).
Figure 223
Figure 224
VFD Filter Input Test
This test will display FL:OP (refer to Figure 225) if
the VFD filter switch is open (poor airflow) or
FL:CL (refer to Figure 226) if the filter switch is
closed (good airflow).
Figure 225
Figure 226
Table 11 (Continued)
Config.
Value
Temp.
Sensor
Present
Network
Board
Present
Card
Reader
Present
Motor
Drive
Pump-
Only
Temp-
Control Fill
Domestic
224 YES YES YES 2SPD NO NO YES
226 YES YES YES 2SPD NO NO NO
228 YES YES YES 2SPD NO YES YES
230 YES YES YES 2SPD NO YES NO
232 YES YES YES 2SPD YES NO YES
234 YES YES YES 2SPD YES NO NO
236 YES YES YES 2SPD YES YES YES
238 YES YES YES 2SPD YES YES NO
240 YES YES YES VFD NO NO YES
242 YES YES YES VFD NO NO NO
244 YES YES YES VFD NO YES YES
246 YES YES YES VFD NO YES NO
248 YES YES YES VFD YES NO YES
250 YES YES YES VFD YES NO NO
252 YES YES YES VFD YES YES YES
254 YES YES YES VFD YES YES NO
B141R
B142R
B144R
B143R