Instruction manual

111
F232151
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Testing Machine and NetMaster Functions
Diagnostics
The following section describes the various diagnostic
tests in the diagnostic mode.
The following Diagnostic tests are available only when
the display shows dIAg.
Control Software Version Number (+001)
Pressure Switches Opening Test (+002)
Access Panel Opening Test (+003)
Coin Vault Opening Test (+004)
Coin Drop #1 Input Test (+005)
Coin Drop #2 Input Test (+006)
Door Switch Input Test (+007)
Door Lock Switch Input Test (+008)
Show Fill Time Test (+009)
Show Drain Time Test (+010)
Temperature Sensor Display Test (+011)
Start Pulse Test (+012)
Heater On Test (+013)
Configuration Display Test #1 (+014)
Configuration Display Test #2 (+015)
Configuration Display Test #3 (+016)
VFD Balance Input Test (+017)
VFD Filter Input Test (+018)
VFD Balance Adjustment Test (+019)
Water Purge Test (+020)
How to Enter Testing Feature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the DELICATES (+) or the COLD (-)
keypad until dlAg appears.
3. Press the START (enter) keypad. Display will
change to +001 indicating the control software
version number test.
4. Press the DELICATES (+) or the COLD (-)
keypad to scroll through the diagnostic test
options.
How to Start Tests
To start a diagnostic test, press the START (enter)
keypad when the desired test # is displayed. For
detailed information on each test, read the appropriate
description.
How to Exit Testing Feature
While pressing and holding the NORMAL keypad
with one hand, press the PERM PRESS keypad with
the other hand. The display will return to the Ready
Mode. Refer to Figure 2.
Control Software Version Number
This displays the current software version number as
Sxxx where xxx is the Control Software Version
Number. Refer to Figure 206.
Figure 206
B027R