Service manual
39201 75
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
42. UPPER BEARING ASSEMBLY
a. Remove transmission assembly. Refer to
Paragraph 41, steps “a” through “u”.
b. Remove screws and lockwashers holding each
support leg to outer tub. Refer to Figure 54.
c. Lift complete weldment assembly (with drive
pulley, brake assembly, lower bearing, and
transmission assembly attached) off outer tub.
IMPORTANT: To prevent porcelain damage, leg
plates must be installed on outer tub flange when
reinstalling support legs. (Plate must be installed on
outside of tub flange). Do not overtighten screws as
this could cause stripping or porcelain damage.
d. Remove three screws holding upper bearing
and housing to bottom of outer tub. Refer to
Figure 59.
NOTE: Replace bearing and housing as an
assembly. Refer to Figure 59.
NOTE: When upper bearing assembly is
reinstalled, threads of cap screws must be secured
with a retaining compound.
Figure 59
CAP SCREW
W453SE3A
OUTER
TUB
UPPER
BEARING
HOUSING
BALL BEARING
UPPER
BEARING
HOUSING