Service manual
56 39201
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37. HUB AND SEAL KIT ASSEMBLY
a. Open loading door.
b. Remove agitator by placing two agitator hooks,
No. 254P4P, under bottom edge of agitator.
Refer to Figure 29.
IMPORTANT: Hooks should be positioned 180
degrees from each other, and must be placed under
agitator vanes for greater stability. If hooks are
placed between vane area, damage to agitator may
occur.
c. Using a rocking motion (back and forth)
carefully lift agitator off drive bell.
d. Remove two screws from bottom edge of front
panel. Refer to Figure 37.
e. Pull bottom of panel away from washer until
hold down clips (located on top flange of panel)
disengage from slots in cabinet top.
f. METERED MODELS:
(1) Unlock and remove meter case service
door.
(2) Remove timer bracket cap screw. Refer to
Figure 9.
(3) Slide timer and bracket toward rear of
meter case to disengage bracket from
shoulder screw. Lift timer and bracket out
of meter case through service door opening
as far as wires will permit.
(4) Remove shoulder screw from inside meter
case.
(5) Remove two cabinet top hold down screws.
Refer to Figure 37.
(6) Remove security bolt (if present) from left
rear corner of cabinet top.
NOTE: When lowering cabinet top into position or
reinstalling cabinet top, pivot outer tub forward far
enough to prevent damaging (bending) loading door
switch lever.
g. If area or space permits, tape loading door
closed and lift cabinet top to a vertical position
by hinging it on the rear hinges.
NOTE: Cabinet top is self supporting, however, a
small chain may be used for additional support.
Refer to Figure 38.
h. Loosen hose clamp and remove filler hose from
outer tub cover. Refer to Figure 46.
NOTE: When installing filler hose, white line on
hose must point toward front of washer. Refer to
Figure 46.
TUB COVER AND GASKET
(1) There are eight tub cover hold-down tabs
which snap over the outer tub flange. Place
your fingers under the flap of the hold-
down tab of the tub cover. Pull out on flap
and at the same time lift upward on cover to
unsnap hold-down tabs from outer tub
flange. One by one, disengage each of the
eight hold-down tabs from outer tub flange
and remove cover.
(2) Lift cover off outer tub and set beside
washer cabinet.
IMPORTANT: When installing outer tub cover,
always use a new cover gasket.
NOTE: Clean and remove any foreign material in
gasket groove of outer tub cover and outer tub
flange.
(3) Starting at the positioning pin located at the
bleach funnel area, lay gasket into gasket
groove of tub cover. Refer to Figure 47.
(4) Using your fingers, press gasket down into
gasket groove of tub cover. Avoid pressing
gasket past ends of hold-down tabs.
IMPORTANT: Care must be taken not to twist or
bunch gasket in any one area to avoid leaks after
assembly.
(5) Install gasket past ends of hold-down tabs
to bottom of gasket groove using semi-
curled end of tub cover gasket tool Part No.
273P4. Refer to Figure 47.
NOTE: Tub cover gasket tool, Part No. 273P4, is
designed to spread open hold-down tabs to prevent
tearing of gasket during installation.
(6) With tub cover tilted at approximately 45
degree angle, insert the positioning pin into
notch on outer tub flange.