Service manual
39201 51
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
35. DOOR SWITCH
a. Remove two screws from bottom edge of front
panel. Refer to Figure 37.
b. Pull bottom of panel away from washer until
hold down clips (located on top flange of panel)
disengage from slots in cabinet top.
c. METERED MODELS:
(1) Unlock and remove meter case service
door.
(2) Remove timer bracket cap screw. Refer to
Figure 9.
(3) Slide timer and bracket toward rear of
meter case to disengage bracket from
shoulder screw. Lift timer and bracket out
of meter case through service door opening
as far as wires will permit.
(4) Remove shoulder screw from inside meter
case.
(5) Remove two cabinet top hold down screws.
Refer to Figure 37.
(6) Remove security bolt (if present) from left
rear corner of cabinet top.
NOTE: When lowering cabinet top into position or
reinstalling cabinet top, pivot outer tub forward far
enough to prevent damaging (bending) loading door
switch lever.
d. Tape loading door closed and lift cabinet top to
a vertical position by hinging it on the rear
hinges.
NOTE: Cabinet top is self supporting, however, a
small chain may be used for additional support.
Refer to Figure 38.
e. Remove screw holding door switch assembly to
underside of cabinet top. Refer to Figure 45.
f. Disconnect wires from door switch.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
g. Remove two screws holding switch to switch
holder. Refer to Figure 45.
h. Remove switch from switch holder.
Figure 45
W487SE1A
DOOR
SWITCH
SWITCH
HOLDER
SWITCH
ASSEMBLY
ATTACHING
SCREW
SCREW