Service manual

34 39201
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
23. METER OR TIMER CASE ASSEMBLY
a. METER CASE REMOVAL (Metered
Models):
(1) Remove two control panel attaching
screws. Refer to Figure 5. Lay assembly
forward on protective pad on cabinet top.
(2) Disconnect timer harness from control
hood harness at disconnect blocks. Refer to
Figure 6.
(3) Unlock and remove meter case service
door.
(4) Remove timer bracket cap screw. Refer to
Figure 9.
(5) Slide timer and bracket toward rear of
meter case to disengage bracket from
shoulder screw. Lift timer and bracket out
of meter case through service door opening
as far as wires will permit.
(6) Disengage wire harness terminal block plug
from timer by pressing in movable locking
tabs (located on each side of terminal block
plug). Refer to Figure 10. Then pull
terminal block plug away from timer.
(7) Disconnect ground wire from terminal on
timer. Refer to Figure 10.
(8) Remove cap screw, lockwashers and nut
holding meter case to end of control hood.
(9) Remove coin drawer.
(10) Remove shoulder screw from inside meter
case.
NOTE: When installing meter case, shoulder screw
must be installed in outer hole. Refer to Figure 9, to
enable timer bracket to slide under screw head.
(11) Remove two screws from bottom edge of
front panel. Refer to Figure 37.
(12) Pull bottom of panel away from washer
until hold down clips (located on top flange
of panel) disengage from slots in cabinet
top.
(13) Remove carriage bolts and locknuts
holding meter case to cabinet top.
(14) Carefully remove meter case and gasket
from cabinet top.
b. TIMER CASE REMOVAL (Nonmetered
Models):
(1) Remove four screws and lockwashers
holding timer and plate to timer case. Refer
to Figure 12.
NOTE: When reinstalling timer and plate,
lockwashers must be between head of screws and
timer plate.
(2) Pull timer and plate out of timer case as far
as wires will permit.
NOTE: Disconnect ground wire from ground
terminal on timer.
(3) Pull wire harness and blocks through into
timer case; then disconnect timer harness
from control hood harness at quick
disconnect block.
(4) Remove two control panel attaching
screws. Refer to Figure 5. Lay assembly
forward on a protective pad on cabinet top.
(5) Remove cap screw, lockwashers and nut
holding timer case to control hood. Refer to
Figure 25.
(6) Remove two cabinet top hold down screws.
Refer to Figure 37.
(7) Tape loading door closed and lift cabinet
top to a vertical position.
(8) Remove carriage bolts, vinyl washers,
lockwashers and nuts holding timer case to
cabinet top.
(9) Support timer case and remove screw and
fiber washer holding rear of case to cabinet
top.
Figure 25
W240SE1A
TIMER
CASE
SCREW
TIMER CASE
ATTACHING HARDWARE