Service manual
32 39201
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
g. DUAL COIN DROP INSTALLATION
(1) Gently work new coin drop into meter case
with the drop’s front face plate down. Refer
to Figure 20.
(2) Carefully pull front of coin drop up and
forward, so the drop’s front face plate
clears the meter case’s door switch bracket.
Refer to Figure 21.
(3) Rest the two coin-return stops on top of the
coin drawer housing, as shown in
Figure 22.
(4) Grasp top of coin drop front face plate
between the two drops, as shown in
Figure 21.
Figure 20
W413SE3A
COIN DROP
FRONT
FACE PLATE
METER
CASE
COIN
DROP
Figure 21
Figure 22
W414SE3A
COIN DROP
FRONT
FACE PLATE
METER CASE
DOOR SWITCH
BRACKET
W415SE1A
COIN
DRAWER
HOUSING
COIN-RETURN
STOPS