To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
f. DUAL COIN DROP REMOVAL
(1) Unlock and open service door.
NOTE: If screw type lock is used, the retainer
bracket must be removed from inside meter case.
(2) Disconnect wire harness from coin drawer
switch and disconnect coin drops at
disconnect plugs.
(3) Press in on locking tabs of service door
switch and remove switch from bracket on
meter case, as shown in Figure 15.
(4) Remove wire harness from multiplier.
Refer to Figure 16. Move wire harness out
of the way.
(5) Remove multiplier from inside meter case.
Refer to Figure 16.
NOTE: Multiplier is held inside meter case by two
Velcro strips.
Figure 15
W408SE3A
SERVICE DOOR
SWITCH
BRACKET
METER
CASE