Service manual
26 39201
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
b. TIMER INSTALLATION (Metered
Models):
(1) Place clutch on timer shaft and tighten
setscrew. Refer to Figure 11.
NOTE: When installing clutch, make sure clutch
moves freely after setscrew is tightened.
(2) Attach timer to timer bracket using two
screws. Refer to Figure 10.
(3) Reconnect wire harness terminal block plug
and ground wire to timer.
(4) Carefully place timer and timer bracket
down inside meter case so keyhole slot in
bracket fits over the head of shoulder
screw. Refer to Figure 9.
(5) After positioning timer bracket over
shoulder screw, slide timer and bracket
forward until bottom front of bracket
contacts rear of coin vault in meter case.
Refer to Figure 9.
(6) While holding timer bracket up against rear
of coin vault, install cap screw and tighten
firmly. Refer to Figure 9.
(7) Make sure wire harness is routed along
bottom of meter case so it will not interfere
with any moving parts in meter case.
c. TIMER REMOVAL (Nonmetered Models):
(1) Loosen two setscrews holding timer knob
to timer shaft. Refer to Figure 12.
(2) Remove four screws and lockwashers
holding timer and plate to timer case. Refer
to Figure 12.
NOTE: When reinstalling timer and plate,
lockwashers must be between head of screws and
timer plate.
(3) Pull timer and plate out of timer case as far
as wires will permit.
NOTE: Disconnect ground wire from ground
terminal on timer.
(4) Pull wire harness and blocks through into
timer case; then disconnect timer harness
from control hood harness at quick
disconnect block.
(5) Remove two screws holding timer to timer
plate. Refer to Figure 12.
(6) Disconnect wires from timer.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
Figure 12
LOCKWASHER
W239SE1A
TIMER
ATTACHING
SCREW
TIMER PLATE
ATTACHING SCREW
TIMER
KNOB
SCREWS
TIMER
TIMER
CASE