39201 13
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
6. MOTOR DOES NOT RUN
7. NO AGITATION
POSSIBLE CAUSE TO CORRECT
Electrical power off, fuse blown or power cord not
plugged in.
• Check laundry room for blown or loose fuse(s) or open
circuit breakers. (Washer itself does not have an electrical
fuse).
Loading door not closed or inoperative switch. • Close door or test switch and replace if inoperative.
Timer improperly set. • Reset timer, or try another cycle.
Inoperative timer. • Test timer and replace if inoperative.
Motor starting functions inoperative. No start; or
motor hums only.
• Refer to Section 7 to check start switch and start windings.
Motor is dead, won’t run. • Refer to Section 7 to check switch and windings.
Motor overload protector has cycled. • Wait two or three minutes for overload protector to reset.
If protector cycles repeatedly, refer to Paragraph 9.
Bind in upper or lower motor bearing. • Remove belt and determine if motor shaft will spin.
Replace motor if shaft is locked up.
Broken, loose or incorrect wiring. • Refer to appropriate wiring diagram.
Power cord is miswired. • Refer to appropriate wiring diagram for correct wiring.
POSSIBLE CAUSE TO CORRECT
Inoperative timer. • Test timer and replace if inoperative.
Inoperative action switch. • Test switch and replace if inoperative.
Motor will not run. • Refer to Section 7 to check switch and windings.
Inoperative pressure switch. • Test switch and replace if inoperative.
Broken, loose or incorrect wiring. • Refer to appropriate wiring diagram.
Broken drive belt. • Replace belt.
Inoperative transmission assembly. • Replace transmission assembly.
Sheared motor pulley roll pin. (Through Serial No.
001113645)
• Remove drive motor and replace roll pin and any other
damaged parts.
Drive motor overload protector has cycled. • Refer to Paragraph 9.
Bind in pump. • Replace pump.
Loading door is open or door switch is inoperative. • Close door or test switch and replace if inoperative.