Specifications

Chemical Injection Using Internal 24VAC Control
Transformer
NOTE: Using the Internal 24VAC 300 Milliamp Control
Transformer is recommended by Alliance Laundry Sys-
tems.
IMPORTANT: DO NOT remove the red jumper wire from
the terminal strip.
There are 3 terminals necessary for this connection option.
Terminal “24VAC COM” is used to connect one side of the
internal control transformer to the external dispenser input
signals common.
The second terminal is used to connect the other side of the
control transformer to the machine output signals common
through a red jumper wire between “24VAC” and “RELAY
COM”. Refer to Figure 27 .
IMPORTANT: Do not use the transformer terminals if
an external power supply is used.
PHM821N_SVG
= Power
= Neutral
7
6
5
4
3
2
1
1. External Supply Power Output
2. Internal Control Transformer
3. RELAY COM Terminal
4. External Dispenser Input Signal Common
5. Red Jumper Wire
6. 24VAC Terminal
7. 24VAC COM Terminal
Figure 27
Chemical Injection Using External AC Power Source
NOTE: An External AC Power Source is NOT provided
by Alliance Laundry Systems.
NOTE: Power for external supplies must not be derived
from the high-voltage main power connection point.
IMPORTANT: The external power must supply power of
240VAC or less and be protected at 3 Amps or less.
1. Remove the red jumper wire installed by the factory between
“24VAC”, and “RELAY COM”.
2. Connect one side of the external power to the “RELAY
COM” and the other to the external dispenser input signals
common. Refer to Figure 28 .
Specifications and Dimensions
F8423301ENR3
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 59