Specifications
PHM553N_SVG
6
5
3
4
2
1
IMPORTANT: Do not attach anything to nozzles. Air gap must be maintained.
Five Compartment Supply Dispenser (Optional)
1. Strain Relief for Liquid Chemical Supply Lines
2. Supply Dispenser Lid
3. Nozzles
4. Dry Supply Cups
5. Dry Supply Insert
6. Polypropylene Supply Dispenser
Figure 24
1. Remove knockout from supply dispenser. Refer to Figure 24 .
Plugs are assembled inside the tubing ring.
2. Install PG connector in hole with strain reliefs, included in the
seal nut.
3. Insert tubes through PG base. Do not remove cups. Tube
should extend into the plastic cup, with the exception of the
softener tube, which should be routed to the outside of the
cup.
4. Tighten the seal nut to prevent tubing from escaping the as-
sembly.
5. Before operating machine, confirm lid is completely closed.
Specifications and Dimensions
F8423301ENR3
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 57