Specifications
100 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full Load
Amps Breaker mm2
NOTE: Follow your local electrical codes. Use only copper conductors, rated for 194°F [90ºC] or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority
having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase cir-
cuit breakers for single phase machines only; three phase circuit breakers for all others.
Table 26
125 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full Load
Amps Breaker mm2
Q 200–240 50/60 3 3 12 16 2.5
N Standard 440-480 50/60 3 3 11 16 2.5
Electric
Heat
74 80 16
P Standard 380-415 50/60 3 3 11 16 2.5
Electric
Heat
65 80 16
NOTE: Follow your local electrical codes. Use only copper conductors, rated for 194°F [90ºC] or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority
having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase cir-
cuit breakers for single phase machines only; three phase circuit breakers for all others.
Table 27
Specifications and Dimensions