Specifications
80 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full Load
Amps Breaker mm2
N Standard 440-480 50/60 3 3 11 16 2.5
Electric
Heat
39 40 4
P Standard 380-415 50/60 3 3 11 16 2.5
Electric
Heat
39 40 4
NOTE: Follow your local electrical codes. Use only copper conductors, rated for 194°F [90ºC] or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority
having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase cir-
cuit breakers for single phase machines only; three phase circuit breakers for all others.
Table 25
100 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full Load
Amps Breaker mm2
Q Standard 208–240 50/60 3 3 17 20 2.5
Electric
Heat
108 125 50
N Standard 440-480 50/60 3 3 11 16 2.5
Electric
Heat
41 50 10
P Standard 380-415 50/60 3 3 11 16 2.5
Electric
Heat
41 50 10
Specifications and Dimensions
F8423301ENR3
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 51