Specifications
60 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full Load
Amps Breaker mm2
X 200–240 50/60 1/3 2/3 17/11 20/16 2.5
Q Standard 200–240 50/60 3 3 11 16 2.5
Electric
Heat
71 80 16
O** 208–240 60 3 3 26 32 2.5
N 440–480 50/60 3 3 37 40 4
P Standard 380-415 50/60 3 3 7 10 2.5
Electric
Heat
37 40 4
NOTE: Follow your local electrical codes. Use only copper conductors, rated for 194°F [90ºC] or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority
having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase cir-
cuit breakers for single phase machines only; three phase circuit breakers for all others.
**M30 Control Models Only.
Table 24
80 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full Load
Amps Breaker mm2
Q Standard 208–240 50/60 3 3 17 20 2.5
Electric
Heat
105 125 50
Specifications and Dimensions
50
©