Specifications
For personal safety and for proper operation, the machine must
be grounded in accordance with state and local codes or accepted
European standards. The ground connection must be made to a
proven earth ground, not to conduit or water pipes. Refer to Fig-
ure 20 and Figure 21 .
L1
L2
L3
SERVICE
GROUND
CHASIS
TB1
PHM700N_SVG
2
1
3
Machines with Electric Heat
1. Grounding Lug: Connect to proven earth ground
2. Customer Input Power Terminals
3. Internal Load Distribution - DO NOT connect customer
power source or load
Figure 20
L1
SERVICE
GROUND
CHASIS
TB1
L2
L3
PHM721N_SVG
1
2
Machines without Electric Heat
1. Grounding Lug: Connect to proven earth ground
2. Customer Input Power Terminal
Figure 21
Machines can be converted for lower voltage operation and/or 50
Hz operation. Refer to conversion label by nameplate for details.
Electrical Specifications
North American Approval
35 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps Breaker AWG mm2
X 200–240 50/60 1/3 2/3 15/8 20/15 12/14 4/2.5
Q Standard 200–240 50/60 3 3 8 15 14 2.5
Electric
Heat
42 50 6 16
O** Standard 208–240 60 3 3 7 20 12 4
Electric
Heat
38 50 6 16
R (Through
7/6/10)
Standard 380–480 50/60 3 3 6 15 14 2.5
Electric
Heat
23 30 10 6
Specifications and Dimensions
F8423301ENR3
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 43