Drain Information
Specifications 35 60 80 100 125 150
Drain connection size,
I.D., in. [mm] with sec-
ond drain:
2.375
[60]
3 [76] 3 [76] 3 [76] 3 [76] 3 [76]
Number of drain outlets 1 1 2 [Uni-
Linc]
1 [M30]
2 [Uni-
Linc]
1 [M30]
2 [UniLinc]
1 [M30]
2
Drain flow capacity, gal/
min. [l/min.]
35
[132]
64
[242]
120
[454]
120
[454]
140 [530] 140 [530]
Recommended drain pit
size, ft
3
[l]
5 [142] 6 [170] 9 [255] 11
[311]
13 [368] 13 [368]
†Sized for one machine using overflow level.
Table 13
Drain Line Sizing/Minimum Drain I.D., in. [mm]
Model
Number of Machines
1 2 3 4
35 3 [76] 3 [76] 3.5 [89] 4 [102]
60 3 [76] 4 [102] 6 [152] 6 [152]
80 4 [102] 6 [152] 6 [152] 8 [203]
100 4 [102] 6 [152] 6 [152] 8 [203]
125 4 [102] 6 [152] 6 [152] 8 [203]
150 4 [102] 6 [152] 6 [152] 8 [203]
Table 14
Water Connection
Connections should be supplied by hot and cold water lines of at
least the sizes shown in the Water Supply Line Sizing table. In-
stallation of additional machines will require proportionately
larger water lines. Refer to Table 16 .
Specifications and Dimensions
F8423301ENR3
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 39