Specifications
UW Models
Specifications 35 60 80 100 125 150
Vibration switch installed STD [V-
speed]
N/A [2-
speed]
STD [V-
speed]
N/A [2-
speed]
STD STD STD STD
Direct Steam Heating [Optional]
Steam inlet connection size,
in. [mm]
0.5 [13] 0.5 [13] 0.5 [13] 0.5 [13] 0.75 [19] 0.75 [19]
Number of steam inlets 1 1 1 1 1 1
Steam re-
quired to
raise bath
temperature
10°F, lbs.
[10°C, kg]
LOW 2.1 [1.7] 3.3 [2.7] 4.6 [3.7] 5.7 [4.6] 6.7 [5.4] 8.3 [6.7]
MED 2.3 [1.8] 3.7 [3.0] 5.2 [4.2] 6.5 [5.2] 7.8 [6.3] 9.5 [7.6]
HIGH 2.7 [2.2] 4.1 [3.3] 6.1 [4.9] 7.6 [6.1] 9.1 [7.3] 11.1 [8.9]
Electrical Heating [Optional]
Total electrical heating ca-
pacity, kW [N/A for 2-speed
models]
15.6 27.4 41.2 [Q-
Volt]
27.4 [N-
Volt]
41.2 [Q-
Volt]
27.4 [N-
Volt]
41.0 [P-Volt]
54.9 [N-
Volt]
N/A
Number of electrical heating
elements
6 6 9 9 12 N/A
Electrical heating element
size, kW
2.6 4.2 4.2 4.2 4.2 N/A
Time re-
quired to
raise bath
temperature,
min per
10°F
[5.5°C]
LOW 2.4 2.4 2.2 2.8 N/A N/A
MED 2.7 2.7 2.5 3.2 N/A N/A
HIGH 3.1 3.0 3.0 3.7 N/A N/A
Noise Emission N/A N/A N/A N/A N/A N/A
Specifications and Dimensions
12
©