Specifications
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
13
803528
The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current), circuit
protected by a 15 ampere fuse, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to Figure 12
to determine correct polarity of the wall receptacle.
Grounding Instructions
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current.
The washer is equipped with a cord having an
equipment-grounding conductor and a three-prong
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
DO NOT modify the plug provided with the washer –
if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that in Figure 12, the
qualified electrician should correct the problem.
Step 9: Check Installation
Refer to Installer Checklist on the back cover of this
manual and make sure that washer is installed
correctly.
Run washer through one complete cycle to make sure
it is operating properly.
DRY2022N
1 L1
2 Ground
3 Neutral Side
4 Round Grounding Prong
5 Neutral
Figure 12
1
2
3
4
5
Standard 120 Volt, 60 Hertz
3-Wire Effectively
Grounded Circuit
0 V.A.C.
120±12
V.A.C.
120±12
V.A.C.
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
W082
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is
properly grounded.
W327
WARNING