Service manual
505894 71
Section 7 Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
66. DRIVE MOTOR
Refer to Figure 44.
a. Remove motor and exhaust assembly. Refer to
Paragraph 51.
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to wiring schematic, Section 8, for
internal motor switch wires.
NOTE: Drive Motor Resistance
120 Volt 2,460 – 3,100 Ohms
240 Volt 10,000 - 13,000 Ohms
Figure 44
2
643 5
1
G
Drive
Motor
Motor and
Exhaust
Assembly
D326SE3A
1
2
4
6
5
3
Motor
Disconnect
Block
Motor
Switch