Service manual
70 505894
Section 7 Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
NOTE: Timer Motor Resistance:
120 Volt, 60 Hz 2,460 – 3,100 Ohms
240 Volt 10,900 – 13,000 Ohms
24 Volt 80 – 130 Ohms
(4) Rotate timer to “cooldown” (5 minutes
before “OFF”). “Infinite” (open) reading
should be found between L2 and H.
(5) Rotate timer to “OFF” position. “Infinite”
(open) reading should be found between L1
and M and between L2 and H.
NOTE: Timer motor power is supplied through M
(1702 and1709 models) or N (all other models)
terminal.
65. FABRIC SELECTOR SWITCH
NOTE: Refer to proper model wiring diagram
when rewiring switch.
a. Set test meter to read Ohms and apply meter
probes to switch terminals.
NOTE: Refer to proper model wiring diagram
when reconnecting wires.
FABRIC SELECTOR SWITCH – 4 Position
L1-1 L1-2
No Heat/Air Fluff – –
Delicate X X
Perm. Press – X
Regular – X
X indicates closed
FABRIC SELECTOR SWITCH
– 3 Position
L1-2 L1-3 L1-1
No Heat/Air Fluff – X –
Delicate/Knits X – X
Regular/Perm. Press X – –
X indicates closed