Service manual

56 505894
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
(8) Remove two screws holding shroud to
heater duct, and remove shroud out through
front of dryer. Refer to Figure 19.
j. Electric Models:
(1) Remove two screws holding element and
plate to heater box, then pull element down
and away from heater box. Refer to
Figure 21.
(2) Remove all wires from terminal block.
NOTE: Refer to appropriate wiring diagram when
rewiring terminal block.
(3) Remove screw holding terminal block to
rear bulkhead. Refer to Figure 38.
k. While supporting bulkhead, remove the four
screws holding rear bulkhead to dryer cabinet,
then lift complete assembly out of dryer. Refer
to Figure 35.
l. Remove heater duct from rear bulkhead. Refer
to Figure 37.
Figure 37
Heater
Duct
Attaching
Screws
Heater
Duct
Attaching
Screws
Heater
Duct
Rear
Bulkhead
D261SE3B