j. Cylinder Glides and Glide Bracket. Refer to
Figure 31.
(1) Unsnap glide from each glide bracket.
(2) Remove screws holding glide bracket to
front bulkhead.
k. Front Cylinder Seal. Refer to Figure 32.
When installing the cylinder seal, it is important
to remember these two steps:
(1) The stitching on the seal must face towards
center of dryer.
(2) The short flap must be glued to the
bulkhead and the long flap left loose.
IMPORTANT: The replacement seal can be
adhered to the bulkhead using No. 22506P Sealant.
This is accomplished by applying a bead of sealant
around the entire flanged area where the felt seal
contacts the bulkhead.
Figure 30
Figure 31
D394S
Cabinet Top
Hold-down
Screw
Front
Bulkhead
Cabinet Top
Hold-down
Screw
Bulkhead
Attaching
Screws
Bulkhead
Attaching
Screws
Slot
Cabinet
Attaching
Screw
Air
Duct
Cabinet
Attaching
Screw
Slot
Cylinder
Seal
Cylinder
Glide
Cylinder
Glide Bracket
Screws
D256SE3C
Figure 32
Bulkhead
Long Flap
Seal Stitching
(Must face towards
center of dryer)
Short Flap
(Must be glued
to bulkhead)
D257SE1A