Service manual

48 505894
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
n. Motor Connection Block Terminals
Remove terminals from the motor wire harness
connection block using No. 283P4 Terminal
Extractor Tool as follows:
(1) Insert the tool into the block on the back of
the terminal being removed. Refer to
Figure 29.
(2) Apply tool pressure to compress the
terminal locking tab on terminal and force
the terminal and wire out back side of
connection block. Refer to Figure 29.
To install terminal in connection block, insert
terminal (with wire securely crimped in place)
into back side of connection block. Push
terminal into connection block until locking tab
on terminal spreads and holds terminal in place.
52. FRONT BULKHEAD ASSEMBLY
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 7.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 16. Remove access panel.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. Refer to
Figure 8. Swing bottom of front panel away
from dryer far enough to disengage hold-down
clips and locators from cabinet top.
d. Disconnect wires from door switch. Refer to
Figure 15. Remove front panel.
NOTE: Refer to wiring diagram when rewiring
switch.
e. Disengage belt from motor and idler pulley.
Refer to Figure 25.
f. Models with Cylinder Light – Disconnect
wires from light receptacle terminals.
g. Models with Cylinder Light – Disconnect
wire clip from front bulkhead.
h. Remove four screws holding bulkhead to front
flange of cabinet and lift complete bulkhead
assembly out of slots in cabinet. Refer to
Figure 30.
i. Remove air duct assembly.
IMPORTANT: When reassembling, be sure seal on
blower fan cover makes airtight seal on flange of
duct. Refer to Figure 22. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
Figure 29
Connection
Block
283P4
Terminal
Extractor
Tool
Terminal
Locking
Tab
D251SE3A
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005