Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
f. Carefully lift air duct out of dryer.
IMPORTANT: When reassembling, be sure seal on
blower fan cover makes airtight seal on flange of
duct. Refer to Figure 22. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
51. MOTOR AND EXHAUST ASSEMBLY
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 7.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 16.
c. Remove screws holding air duct to front
bulkhead (inside cylinder). Refer to Figure 23.
IMPORTANT: When reassembling, be sure seal on
blower fan cover makes airtight seal on flange of
duct. Refer to Figure 22. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted, which can adversely affect dryer
performance.
d. Disconnect wires from thermostat.
NOTE: Refer to wiring diagram when rewiring
thermostat.
e. Remove screw holding ground wire to dryer
base. Refer to Figure 24.
f. Remove cylinder belt from idler and motor
pulleys. Refer to Figure 25.
g. Disengage motor wire harness terminal block
from motor switch by pressing in on the
movable locking tabs (located on each end of
the terminal block) and pulling away from
motor. Refer to Figures 28 and 29.
h. Remove two screws holding motor mounting
bracket to dryer base. Refer to Figure 24.
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Figure 24
DRY1824S
Cover
Attaching
Screws
Ground
Wire
Motor Mount
Attaching
Screws
Thermostat