Service manual
18 505894
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
16. IGNITION CONTROL FLASHES
Refer to Figure 1.
NOTE: This control will lock-out the igniter after four failed attempts at ignition. The control can be reset by
opening loading door, waiting 1 minute, then closing loading door. If door is closed before waiting 1 minute, the
control will re-enter lockout. The red light will flash a “Flash Code” when the control is in the lock-out mode. The
light will flash on for 1/4 second then off for 1/4 second for each number. The pause between flash codes is 2
seconds. These flashes are caused by the control’s diagnostic test and can be interpreted by reading the following:
FLASH CODE POSSIBLE CAUSE TO CORRECT
Constant Light Internal failure. • Reset dryer. (Refer to NOTE above.) If
condition persists, then replace control.
One Flash Air in gas line. • Purge air from gas line.
Sensor coated with Aluminum Oxide. • Wipe sensor clean or replace sensor if
necessary.
Incorrect gas pressure. • Check for correct gas pressure. If gas pressure
is incorrect, then contact local gas company.
Gas shut-off valve closed. • Open gas shut-off valve.
Four Flashes Internal failure. • Reset dryer. If condition persists, then replace
control.
Loose or disconnected wiring. • Check all wiring leading to, or coming from,
the control module for secure connections.
Open Igniter/igniter sensing circuit/
voltage measurement circuit.
• Check igniter and all circuits, replace if
necessary.
Five Flashes Loose or disconnected wiring. • Check all wiring leading to, or coming from,
the control module for secure connections.
Inoperative gas valve. • Check gas valve and replace if necessary.
Inoperative sensor. • Replace sensor/igniter.
Six Flashes Loose or disconnected wiring. • Check all wiring leading to, or coming from,
the control module for secure connections.
Incorrect wiring. • Check wiring diagram and make sure dryer is
wired correctly.
Incorrect polarity. • Contact a professional electrician to check the
polarity, and correct any problems.