Service manual
10 505894
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2. DRYER STOPS IN CYCLE; QUITS AFTER THE FIRST FEW LOADS; HAS A BURNING SMELL;
CYCLES ON MOTOR THERMAL PROTECTOR
POSSIBLE CAUSE TO CORRECT
Incorrect Voltage. • Refer to nameplate in door well for correct voltage.
• Refer to Installation Instructions (supplied with dryer)
for electrical requirements.
Clothes load too large. • Remove part of load. A normal washer load is a normal
dryer load. Maximum load: dryer cylinder one half full of
wet clothes.
Clothes cylinder is binding. • Check cylinder for binding and “out of round” condition.
• Check front and rear bulkheads for warping.
• Check support rollers for binding.
• Check cylinder seals and glides for wear or damage.
• Check for clothes lodged between cylinder baffle and
bulkhead.
Broken, loose or incorrect wiring. • Refer to wiring diagram.
Motor switch functions inoperative.
Short in motor winding.
• Refer to Paragraph 66 to check switch and windings.
Clothes item caught in fan. • Check fan for obstruction.










