Service manual

10 505894
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2. DRYER STOPS IN CYCLE; QUITS AFTER THE FIRST FEW LOADS; HAS A BURNING SMELL;
CYCLES ON MOTOR THERMAL PROTECTOR
POSSIBLE CAUSE TO CORRECT
Incorrect Voltage. Refer to nameplate in door well for correct voltage.
Refer to Installation Instructions (supplied with dryer)
for electrical requirements.
Clothes load too large. Remove part of load. A normal washer load is a normal
dryer load. Maximum load: dryer cylinder one half full of
wet clothes.
Clothes cylinder is binding. Check cylinder for binding and “out of round” condition.
Check front and rear bulkheads for warping.
Check support rollers for binding.
Check cylinder seals and glides for wear or damage.
Check for clothes lodged between cylinder baffle and
bulkhead.
Broken, loose or incorrect wiring. Refer to wiring diagram.
Motor switch functions inoperative.
Short in motor winding.
Refer to Paragraph 66 to check switch and windings.
Clothes item caught in fan. Check fan for obstruction.