Specifications
Installation
.
Use the three silver screws removed in step 3 to
attach the wires from the new power cord and the
other end of the green ground wire to the terminal
block as shown in Figure 15.
NOTE: Green ground wire must be connected to
center (neutral) terminal of terminal block.
8
5
1
2
3
4
5
6
7
8
DRY2015N
Ground to Neutral Wire
Neutral Terminal
L2 Terminal
Center (Neutral) Wire
Strain Relief (not supplied with dryer)
Green Ground Screw
L1 Terminal
Ground Wire
6. Tighten all screws and reinstall access cover
removed in step 2.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
.
.
.
10.
Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of cabinet.
Reinstall access cover and screw.
Restore power to dryer.
Figure 15
512023 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 19