Specifications

Installation
Electric Dryers with 3-Wire Plug (Requires
Conversion)
(120/240 Volt, 60 Hertz, 3-Wire Installation)
(120/208 Volt, 60 Hertz, 3-Wire Installation)
NOTE: The wiring diagram is located inside the
control hood.
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer's responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
W512
Grounding Instructions
This dryer must be connected to a grounded
metal, permanent wiring system; or an
equipment-grounding conductor must be run
with the circuit conductors and connected to the
equipment-grounding terminal or lead on the
dryer.
The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz, single
phase circuit, AC (alternating current) circuit,
fused at 30 Amperes (the circuit must be fused
on both sides of the line). Electrical service for
the dryer should be of maximum rated voltage
listed on the nameplate. Do not connect dryer
to 110, 115, or 120 Volt circuit. Heating
elements are available for field installation in
dryers which are to be connected to electrical
service of different voltage than that listed on
nameplate, such as 208 Volt.
If branch circuit to dryer is 15 feet (4.57 m) or
less in length, use No. l0 A.W.G. wire (copper
wire only), or as required by local codes. If over
15 feet (4.57 m), use No. 8 A.W.G. wire (copper
wire only), or as required by local codes. Allow
sufficient slack in wiring so dryer can be moved
from its normal location when necessary.
The power cord (pigtail) connection between
wall receptacle and dryer terminal block IS NOT
supplied with dryer. Type of pigtail and gauge
of wire must conform to local codes and with
instructions mentioned on the following pages.
The method of wiring the dryer is optional and
subject to local code requirements. Refer to
Figure 11.
16 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512023