Service manual
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
F8343001
38
13. Machine Fills at Wrong Temperature
CHM
Machine Fills at Wrong Temperature
Are both hot and
cold fill valves
on?
Turn water valves on.
No
Are filter screens
in fill hoses clear?
Clean/replace filter screens as necessary.
No
Yes
Is there voltage
at appropriate fill
valves?
Check voltage at fill valves. Make sure correct water
temperature connected to correct valve (i.e. hose
connected to hot water valve to hot water inlet, hose
connected to cold water valve to cold water inlet).
Yes
No
Is temperature selector switch
operational (refer to Machine
Fills at Wrong Temperature
Schematic)?
Repair/replace switch as necessary.
No
Yes
Refer to “No Output” flowchart.
Yes
A
CHM496S