Operating instructions

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
F232136
12
E:Ub – When computer is unable to balance a
load during the drain step before the last extract
step, computer will run the last extract step at
lowest spin speed and display “E:Ub” for one
minute after the door is opened.
Alrm – When the computer senses a Break-In
Alarm error caused by the service door and Coin
Vault switches.
Off – When the computer senses a Break-In
Alarm error caused by the service door and Coin
Vault switches and the “shut down” option is
turned on.
The following errors are non-recoverable. Power to
machine must be shut off to reset the control. Consult
a qualified technician in non-recoverable error
occurrences.
E:FL – When computer has not received input
from water level switch indicating that
programmed water level has not been reached
61 minutes into fill, computer shuts off water fill
valves, aborts cycle, sounds an alarm and
displays “E:FL.
E:Pr – When computer receives input from water
level switch indicating that switches are opening
in an incorrect sequence, computer aborts cycle,
sounds an alarm, and displays “E:Pr.
E:dr – When computer has not received input
from water level switch indicating an empty
condition 31 minutes into a drain step, computer
aborts cycle, sounds an alarm and displays
“E:dr.
E:dO – When computer senses that door has
opened while a cycle is in progress, computer
aborts cycle, sounds an alarm and displays
“E:dO.
E:SP – When computer fails to receive proper
input from output board, computer sounds an
alarm and displays “E:SP.
E:OP or E:SH – When computer senses a
temperature less than five degrees Fahrenheit
during the fill cycle step (“OP”); or senses a
temperature greater than 220 degrees Fahrenheit
during a fill cycle step (“SH”), the computer
aborts cycle, sounds an alarm and displays error
code. Models with heat and temperature control
only.
E:Ht – When the computer (heater) requires
more than two hours to heat water to
programmed temperature, computer turns off
heater, continues the cycle to the end and
displays “E:Ht.Models with heat only.
EI:xx – When the computer senses an Infra-Red
Communication error, the display will read
“EI:xx” where “xx” indicates the error
description as shown in Table 1 .
Error
Display
Error
Description
:00 General communication error
:01 Bad transmission
:02 Device timeout
:03 Invalid command code
:04 Expecting upload request
:05 Invalid or out-of-range data
:06 Invalid data code
:07 Error writing to RTC
:08 Error writing to EEPROM
:09 CRC-16 error
:0A Framing error
:0F Invalid wakeup or IR disabled
Table 1