Specifications
80 Pound Capacity Models (CE Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er mm2
P Standard 380-415 50/60 3 3 7 10 2.5
Electric Heat 33 40 4.0
V-Speed Models
N Standard 440-480 50/60 3 3 7 10 2.5
Electric Heat 37 40 4.0
X 200–208 50/60 1/3 2/3 17/11 20/16 2.5
220-240
Q Standard 200–208 50/60 3 3 11 16 2.5
Electric Heat 220-240 72 80 16.0
P Standard 380-415 50/60 3 3 7 10 2.5
Electric Heat 33 40 4.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 35
100 Pound Capacity Models (CE Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er mm2
F and V-Speed Models
N Standard 440-480 50/60 3 3 7 10 2.5
Electric Heat 38 40 4.0
X 200–208 50/60 1/3 2/3 17/11 20/16 2.5
220-240
Q Standard 200–208 50/60 3 3 11 16 2.5
Electric Heat 220-240 74 80 16.0
Table 36 continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
60 Part No. F8429301ENR15