Specifications
CE Approval
20 Pound Capacity Models (CE Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er mm2
F and V-Speed Models
N 440-480 50/60 3 3 2 6 2.5
X 200–208 50/60 1/3 2/3 4/3 6 2.5
220-240
Q Standard 200–208 50/60 3 3 3 6 2.5
Electric Heat 220-240 21 25 2.5
P Standard 380–415 50/60 3 3 2 6 2.5
Electric Heat 13 16 2.5
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 31
30 Pound Capacity Models (CE Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er mm2
F and V-Speed Models (unless otherwise noted)
N 440-480 50/60 3 3 3 6 2.5
X (F-speed) 200–208 50/60 1/3 2/3 5/4 6 2.5
220-240
X (V-speed) 200–208 50/60 1/3 2/3 7/4 10/6 2.5
220-240
Q Standard 200-208 50/60 3 3 4 6 2.5
Electric Heat 220-240 22 25 2.5
P Standard 380–415 50/60 3 3 3 6 2.5
Electric Heat 13 16 2.5
Table 32 continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
57 Part No. F8429301ENR15