Specifications
80 Pound Capacity Models (North American Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er AWG mm2
F-Speed Models
X 200–208 50/60 1/3 2/3 12/8 15 14 2.5
220-240
Q Standard 200-208 50/60 3 3 8 15 14 2.5
Electric
Heat
220-240 72 80 4 25.0
N Standard 440-480 50/60 3 3 5 15 14 2.5
Electric
Heat
37 40 8 10.0
P Standard 380-415 50/60 3 3 5 15 14 2.5
Electric
Heat
33 40 8 10.0
V-Speed Models
X 200-208 50/60 1/3 2/3 15/9 20/15 12/14 4/2.5
220-240
Q Standard 200-208 50/60 3 3 9 15 14 2.5
Electric
Heat
220-240 72 80 4 25.0
N Standard 440-480 50/60 3 3 6 15 14 2.5
Electric
Heat
37 40 8 10.0
P Standard 380-415 50/60 3 3 6 15 14 2.5
Electric
Heat
33 40 8 10.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 29
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
55 Part No. F8429301ENR15